900-362 Installation
 

Connect Power Supply (12vdc 500ma min.) to Power Terminal as shown.

Connect Zone Alarm terminal to closed circuit device. If J1 is set in the remote reset-disarm position it is necessary to connect all unused alarm zones to - on power supply.

Set Jumper J1 to desired position
Local and remote Reset/Disarm short 1 and 2
Remote only Reset/Disarm short 2 and 3

Remote reset switch should be a normally open momentary type device. Use a maintained type switch for remote disarm.

The remote signal terminal goes negative when the zone is in the alarm condition and may be used to operate a remote light or buzzer with a maximum of 200ma output.

Adjust tone volume control to desired level.