Door Monitors Monitor Panel 900-362 |

Features * EIGHT CLOSED LOOP ALARM CIRCUITS * TAMPER PROOF TONE VOLUME CONTROL * TONE SILENCE SWITCH WITH AUTOMATIC RECALL * MOUNTS TO STANDARD 5 GANG BOX * ADJUSTABLE FOR EITHER LOCAL OR REMOTE RESET/DISARM * SURFACE, FLUSH OR DESK TOP MOUNTING General Description The EEI model 900-362 Monitor Panel will monitor eight (8) closed circuit zones.
Each Zone has provisions for individual remote signal output during alarm and remote
reset/disarm capabilities. An alarm silencing switch is provided which will
silence the alarm tone but the alarm indicating LED will remain on. The tone
will remain silenced for approximately 30 seconds after which time the tone will
resound unless the activated zone has been reset. A volume control is located on the rear of the panel to adjust the tone level output. Also located on the rear of the panel is a jumper which may be used to select local and remote operation or remote only operation. In the local and remote position the system may be reset or disarmed from the switches on the front of the panel or from remote switches mounted elsewhere. In the remote position the panel switches are inactive and the system may only be rest or disarmed from a remote location. Status conditions are indicated by L.E.D. indicators and audible tone. Power: Green LED-on. Zone disarmed: Amber and Red LED-off. Zone armed: Amber LED-on. Zone Alarm: Amber and Red LED-on and tone sounds. Associated Equipment Installation 900-362 Door Monitor Panel Accessory Devices Click Here for Accessory Diagrams |
Part No. 900-051 900-052 900-053 900-054 900-055 900-056 900-057 500-086 100-830 100-840 900-825 900-355 |
Description Keypad w/Relay - 1 Gang Plate Pushbutton Switch - Momentary - 1 Gang Plate Keyswitch - 1 Gang Plate Audible Signal - 1 Gang Plate Pushbutton Switch - w/Audible Signal - 1 Gang Plate Keyswitch w/Audible Signal - 1 Gang Plate Pushbutton and Keyswitch w/Audible Signal - 1 Gang Plate Desk Mounting Kit Box - Flush Mount - 5 Gang Box - Surface Mount - 5 Gang Power Supply - 12vdc Magnetic Door Contact |
Connect Power Supply (12vdc 500ma min.) to Power Terminal as shown. Connect Zone Alarm terminal to closed circuit device. If J1 is set in the remote reset-disarm position it is necessary to connect all unused alarm zones to - on power supply. Set Jumper J1 to desired position Local and remote Reset/Disarm short 1 and 2 Remote only Reset/Disarm short 2 and 3 Remote reset switch should be a normally open momentary type device. Use a maintained type switch for remote disarm. The remote signal terminal goes negative when the zone is in the alarm condition and may be used to operate a remote light or buzzer with a maximum of 200ma output. Adjust tone volume control to desired level. |