Door Monitors
Monitor Panel
900-362
Features

* EIGHT CLOSED LOOP ALARM CIRCUITS

* TAMPER PROOF TONE VOLUME CONTROL

* TONE SILENCE SWITCH WITH AUTOMATIC RECALL

* MOUNTS TO STANDARD 5 GANG BOX

* ADJUSTABLE FOR EITHER LOCAL OR
   REMOTE RESET/DISARM

* SURFACE, FLUSH OR DESK TOP MOUNTING


General Description

The EEI model 900-362 Monitor Panel will monitor eight (8) closed circuit zones. Each Zone has provisions for individual remote signal output during alarm and remote reset/disarm capabilities. An alarm silencing switch is provided which will silence the alarm tone but the alarm indicating LED will remain on. The tone will remain silenced for approximately 30 seconds after which time the tone will resound unless the activated zone has been reset.

A volume control is located on the rear of the panel to adjust the tone level output. Also located on the rear of the panel is a jumper which may be used to select local and remote operation or remote only operation. In the local and remote position the system may be reset or disarmed from the switches on the front of the panel or from remote switches mounted elsewhere. In the remote position the panel switches are inactive and the system may only be rest or disarmed from a remote location.

Status conditions are indicated by L.E.D. indicators and audible tone. Power: Green LED-on. Zone disarmed: Amber and Red LED-off. Zone armed: Amber LED-on. Zone Alarm: Amber and Red LED-on and tone sounds.


Associated Equipment


















Installation























900-362 Door Monitor Panel Accessory Devices

Click Here for Accessory Diagrams
Part No.

900-051
900-052
900-053
900-054
900-055
900-056
900-057

500-086
100-830
100-840
900-825
900-355
Description

Keypad w/Relay - 1 Gang Plate
Pushbutton Switch - Momentary - 1 Gang Plate
Keyswitch - 1 Gang Plate
Audible Signal - 1 Gang Plate
Pushbutton Switch - w/Audible Signal - 1 Gang Plate
Keyswitch w/Audible Signal - 1 Gang Plate
Pushbutton and Keyswitch w/Audible Signal - 1 Gang Plate
Desk Mounting Kit
Box - Flush Mount - 5 Gang
Box - Surface Mount - 5 Gang
Power Supply - 12vdc
Magnetic Door Contact

Connect Power Supply (12vdc 500ma min.) to Power Terminal as shown.

Connect Zone Alarm terminal to closed circuit device. If J1 is set in the remote reset-disarm position it is necessary to connect all unused alarm zones to - on power supply.

Set Jumper J1 to desired position
Local and remote Reset/Disarm short 1 and 2
Remote only Reset/Disarm short 2 and 3

Remote reset switch should be a normally open momentary type device. Use a maintained type switch for remote disarm.

The remote signal terminal goes negative when the zone is in the alarm condition and may be used to operate a remote light or buzzer with a maximum of 200ma output.

Adjust tone volume control to desired level.
Click on image for full view of  instructions and illustration