Patient Protector
900-361










FEATURES

* *EASILY MOUNTED TO BED OR WHEELCHAIR BY VELCRO STRAP

*ALARM ACTIVATED WHEN DISK IS PULLED AWAY FROM SENSOR

*ALARM ACTIVATED WHEN BUTTON IS DEPRESSED ON CALL CORD

*ADJUSTABLE MAGNETIC SENSOR CORD

*LOCAL AUDIBLE ALARM WHEN ACTIVATED

*JACK FOR CONNECTING TO NURSE CALL
SYSTEM

*OPERATES ON ONE 9 VOLT BATTERY

*LOW BATTERY ALERT

*CAN BE USED FOR ALARM WHEN INTERIOR
DOOR IS OPENED

GENERAL DESCRIPTION

The 900-361 Patient Protector is designed for home or institution to alert caregiver if patient exceeds predetermined movement from bed or wheelchair, or patient needs assistance by depressing button on optional 6' call cord. Battery operation allows the Patient Protector to be used as a mobile monitoring system. Simply clip the corded magnet assembly to the patients clothing and attach the monitor unit to the bed or wheelchair with the velcro strap and the system is working.

The Patient Protector can also be used in conjunction with an existing nurse call system by simply plugging in optional 900-809 adapter cable to room call station.


ACCESSORIES

900-801CALL CORD
900-809SYSTEM CORD


PARTS

500-088MAGNET/CORD ASSEMBLY
100-432VELCRO ADHESION STRAPS
100-437BATTERY


GENERAL OPERATION

Removal of magnetic cord assembly or depressing optional call cord will cause sounder to activate and LED to flash. IF LED IS STEADY UPON ALARM ACTIVATION, REPLACE BATTERY IMMEDIATELY. Units should be checked daily for proper operation.

BATTERY REPLACEMENT

Remove the four screws on back of Patient Protector and replace with standard 9V battery.

OPERATION FOR MOVEMENT MANAGEMENT

1.     Attach the Patient Protector to wheelchair or bed by the velcro strap.
2.     Attach clip to patients garment.
3.     Place the magnetic end of string assembly on the silver disc on the      face of the unit. Adjust string to allow for required movement before alarm.
4.     Removal of disk will activate local alarm
.



OPERATION FOR LOCAL ALARM

1.       Attach Patient Protector to desired location by velcro strap.
2.       Plug optional 900-801 call cord into jack marked "LOCAL".
3.       Depressing momentary button on call cord will sound local alarm until button is released.


OPERATION FOR SYSTEM ALARM

1.       Attach Patient Protector to desired location by velcro strap.