Visual and Audiovisual
Control Panel
900-203











FEATURES

*  REGULATED 24VDC POWER SUPPLY

*  FOUR LEVEL FLASHER

*  MAINTAINED COMMON ALARM CONTACTS

*  80 POSITIONS TERMINAL BOARD

*  8 FIELD SETTABLE ZONES

*  OPTIONAL AMPLIFIER FOR AUDIO SYSTEMS
GENERAL DESCRIPTION

THE ENGINEERED ELECRONICS MODEL 900-203 CONTROL PANEL IS THE POWER SOURCE AND CENTRAL TERMINATING LOCATION FOR THE DS-2000 NURSE CALL SYSTEM.  ALL FLASH RATES AND TONES ARE FUNCTIONS OF THIS UNIT.


ENGINEERS' SPECIFICATIONS
















Standard Equipment






Optional Equipment




Drawing and Instructions





Dimensions





(1)     The equipment described shall be manufactured and assembled entirely in the United States of America.
(2)     There shall be separate circuit boards for the Power Supply, Flasher, Terminal Board and optional Amplifier. Replacement of any board shall be possible without the use of any special tools for ease of maintenance.
(3)     There shall be an AC power Switch with power on indicator.
(4)     The power source shall be a 24vdc switcher power supply with built-in current limiting of 3amps.  There shall be a 3amp resetable fuse for output to field wiring, and a 3amp resetable fuse for output to console control.
(5)     The Power Supply shall have LED indicators showing status of supply voltage, 24 vdc to Field voltage, and 24 vdc to Master Voltage.
(6)     The control shall be designed to function as an Audio/Visual system by inserting an optiona
modular type amplifier board. The Amplifier shall include separate Volume Controls for handset talk, handset listen, and panel speaker.  There shall also be a separate control for Amplifier gain.
(7)     The Flasher shall provide 4 levels of call signaling to Accommodate Normal Patient Calls and 3 levels of Emergency Calls.
(8)     The Flasher shall have a set of Dry Contacts, which shall be settable for either normally open or normally closed operation.
(9)     The terminal board shall provide 80 individual screw terminals for point wire termination, 8 Zone outputs,  field settable in-groups of 5 positions, and Interconnect Cable plugs for connecting to Master / Annunciator.
(10)   The control panel shall come from the factory a complete assembly and should require only field wire connections to make the system functional.
(11)   The 900-203 Control panel shall conform to Underwriter's Laboratory (UL 1069).
500-158
500-170
500-172
100-790
POWER SUPPLY
FLASHER CONTROL
TERMINAL BOARD
POWER SWITCH
500-174
100-193
100-180
MOTHERBOARD
TRANSFORMER
CAPACITOR
500-175
100-884
AMPLIFIER
CABINET
Field wiring Visual Nurse Call System
Field wiring Audio/Visual Nurse Call System
Field wire Connections
301-101
301-102
201-101
900-203 Panel
100-884 Cabinet
22" H x 16" W
24" H x 21" W x 4 1/2" D